auto-immu 120
Auto-Immu 120
Auto-Immu 120 are used to count and identify blood cells at high speed and accuracy. Auto-Immu 120 analyzers are used to conduct a complete blood count (CBC), which is usually the first test requested by physicians to determine a patients general health status. A complete blood count includes red blood cell (RBC), white blood cell (WBC), hemoglobin, and platelet counts, as well as hematocrit levels.
Auto-Immu 120 immunology analyzer uses Coulter’s Principle to find the size and volume of the cell. The sample is lysed and dissolved into an electrolyte solution in a container, which also holds a smaller container. The smaller container has 2 pumps running to and from its solution, one creating a vacuum and the other replacing the lost solution. The smaller container has a small hole (an orifice) near the bottom of the container. Coulter’s principle is applied through the use of two electrodes. One electrode (the internal electrode) is within the smaller container, and the other (the external electrode) is outside of the smaller container but within the electrolyte/sample solution. As the vacuum draws the sample cells through the orifice, the cell momentarily causes electrical resistance to the current as it passes through the orifice. This resistance is recorded, measured, amplified, and processed which can then be interpreted by the computer into a histogram. The 3-part analyzer is able to differentiate between 5 types of WBC’s, neutrophils, lymphocytes, and monocytes.
Technical Specification
Technology
- 3-D Topographic Map
- Integral Titanium Incubation System
- Laser Scatter Technology
- Flow Cytometry Technology
- Cyanide Free Reagents
- Autoloader & Close Tube
- Random Direction Tube Barcode Scanning Technology(Optional)
Parameters
Regular Parameters:
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, MON%, EOS#, EOS%, BAS#, BAS%
Research Parameters:
ALY#, ALY%, IG#, IG%
2 histograms, 2 scattergrams
Test Speed
Autoloader Mode: 60 Samples/hour
Close Tube Mode: 60 Samples/hour
Test Mode
CBC+5DIFF, CBC
Performance
Sample Volume
≤10ul
QC and Calibration
Multiple QC rules, including L-J, X-B etc.
Auto and manual calibration function for both whole blood mode and pre-diluted blood mode
Power Supply
100V-240V, 50Hz/60Hz
Sampling Mode
Autoloader: 50 tubes, Auto mixing, Random Direction Tube Barcode Scanning Technology
Close Tube: STAT Priority, Support both whole blood and capillary blood samples
Weight
75KG
Dimension
61cm(L)x76cm(W)x61cm(H)
Working Environment
- Temperature: 10-30˚C
- Humidity: 20-80%
- Air pressure: 70-106KPa
- Working Latitude: ≤3500m